L24 EEG Data Acquisition Amplifier System

L24/L16 EEG Data Acquisition Amplifier

Made in SAGURA

High Quality Medical EEG/PSG Data Acquisition Amplifier Systems incl. Isolated Medical Grade Power System and Data Transmission Optical Isolation for highest Patient Safety are manufactured in Germany and CE marked according to 93/42/EWG European Community directive. Simultaneous recording of high quality EEG traces and high resolution multicamera digital video offer enhanced diagnostic capabilities (e.g. in Epilepsy and PSG diagnostics).

Downloads:

Advanced Features:

Specifications:

All specifications are subject to change without notice.

* EEG Channels
Sampling rate per channel:100 to 4800 sps
Sensitivity:0.1 - 3000 uV/mm
Input range:+-4 mV
High pass filter:from 0.001 to 60 sec
Low pass filter:from 0.01 to 2000 Hz
ADC converter:16 bit
Common-mode rejection ratio at 10 Hz frequency:130 dB
Suppression ratio of power frequency by notch filter:50 dB
Peak-to-peak noise level measured at 10 kOhm resistance:0.6 uV
Input impedance, not less than:1000 GOhm
Interchannel damping, not less than:80 dB
Calibration:Auto
Control of electrode setting according to impedance measurement:Yes
Control of ground electrode setting:Yes
Oversample ratio output rate:250:1
Oversample ratio reduction filters:2:1 .. 25:1
Antialiasing/Rejection filters, not less than-30db/-80db
* Connect to PC or Notebook
Amplifier Interface for data transfer and +5V Power:USB or RS232, 5V/Pin9
Maximum data transfer rate for RS232:3 Mbps
PCIexpress-RS232 Adapter incl. +5V/+12 on Pin9ex-44092
USB-RS232 Adapter incl. +5V on Pin9Available
LAN-RS232 Adapter + PowerBox, +5/+12VAvailable
WLAN-RS232 Adapter + PowerBox +5/+12V or LiPo AccuAvailable
Number of EEG, EMG, EOG, ECG channels:up to 24
Number of polygraphic channels:0
Number of breath channels:0
DC channels for external devices:0
* External Stimulator
Stimulator Interface, in/out:RS232,9600,n,8,1
Synchronized precision :0.1 msec
* External CO2/O2/CPAP/SpO2 devices
Interface for external devises, in/out:RS232
* Auditory Stimulator
Pause for each Stimul0.1 sec steps
Number of different wave files/SoundProgram10
Number of SoundPrograms:9x30
Maximum duration of SoundProgram:600 min
Marking for each StimulYes
* Patients Joysticks
Number:one or two
Trace for X- and Y- coordinates:Yes
Marking for each of Buttons:Yes
* Photic Stimulator
Stimulus duration:5 - 1000 ms
Stimulation frequency:0.5 - 60 Hz
* Safety
Patient Isolation Electrical safety:EN60601, BF
Electrode connectors:SUB-D 25 pins or DIN 42802

24 Channels EEG Amplifier System, opt. A:

24 Channels EEG/PSG Acquisition Amplifier System